1.PH Analyzer Product Introduction
ZS3PH Analyzer is an instrument capable of online monitoring of pH. It integrates pH sensors and measurement module communication storage, and can quickly and accurately record key parameters in water bodies. At the same time, the instrument supports the expansion of water quality multi-parameter sensors, including but not limited to pH value, dissolved oxygen (DO), conductivity, turbidity, temperature, ammonia nitrogen, etc., which can be combined and configured according to different needs and applications, record and store historical monitoring data, alarm history records, and support historical data export.xlsx. The RS485 interface supports MODBUS-RTU communication protocol to facilitate users to freely communicate with PLC, DCS, configuration software, DTU and other devices to connect and transmit data.
2. Application fields of PH Analyzer
Online multi-parameter water quality detectors are widely used in the monitoring and control of various water bodies, including but not limited to the following areas:
1. Water plant: used to monitor the pH value, dissolved oxygen, turbidity and other parameters of tap water to ensure the safety and hygiene of tap water.
2. Groundwater monitoring: used to monitor groundwater parameters such as pH, conductivity, and temperature in order to promptly detect and resolve water quality problems.
3. River and lake monitoring: used to monitor the water quality of rivers and lakes, such as dissolved oxygen, turbidity, ammonia nitrogen and other parameters, so as to take timely pollution control measures.
4. Ocean monitoring: used to monitor the water quality of the ocean, such as salinity, dissolved oxygen, temperature and other parameters, so as to timely detect and control marine pollution.
5. Sewage treatment: used to monitor sewage water quality parameters, such as pH, COD, ammonia nitrogen, etc., in order to control and adjust the sewage treatment process.
6. Industrial production: used to monitor water quality in industrial production processes, such as pH, conductivity, dissolved oxygen and other parameters, so as to adjust the process in time and ensure product quality.
7. Scientific research: used for water quality monitoring in the field of scientific research, such as lake eutrophication, climate change, etc.
3. Technical Features of PH Analyzer
1. High reliability: suitable for long-term work in the field environment, stable measurement and strong anti-interference ability.
2. Flexible and portable: Each probe can be freely combined, replaced independently, and plug and play.
3. Scalability: Various sensors can be freely combined.
4. Multiple applications: on-site rapid measurement, emergency monitoring, or long-term online monitoring of groundwater, river water, lake water, and urban pipe network water.
5. Tough shell: ABS+PC material, corrosion-resistant, can work normally for a long time.
6. Compact structure: can be installed in small places.
7. Communication connection: RS485 expansion interface, master/slave interface isolation and independent communication.
4. PH Analyzer Technical Parameters
| Display Output | 4.3-inch touch screen with strong LED backlight, can be operated under direct sunlight |
| power supply | DC power supply: DC12V |
| Power consumption | The power consumption of the instrument is about 12V / 1W |
| Sound Output | buzzer |
| Communication Protocol | Standard RS485 Modbus-RTU protocol and device master/slave transmission channel support |
| Main Materials | ABS+PC material |
| Storage temperature | -20 to 70°C |
| Operating temperature | -10 to 50°C |
| Protection level | IP65 |
| size | 175mm*140mm*49mm(length×width×height) |
| weight | About 0.5KG |
5. PH Analyzer Sensor Configuration
| Model | Name | Measurement range | Principle | Measurement accuracy | Resolution | Is it standard equipment | Note |
| S3 | pH | 0~14 (ph) | Electrochemistry (salt bridge) | ±0.1PH;±0.1℃ | 0.01 | √ | With warm supplement |
Yangmei, a characteristic fruit in southern China, is highly favored by consumers for its sweet and sour taste, as well as its rich medicinal and edible values. As a perennial plant, its growth is influenced by the comprehensive effects of the current year's climate, the previous year's envi...
A Portable Weather Station for firefighting is a lightweight and multi-functional weather monitoring device specially designed for fire rescue scenarios. It is mainly used to monitor the meteorological conditions at the fire scene in real-time, helping firefighters assess the development trend of th...
The Negative oxygen ion monitoring station, as the core quantitative tool of a "natural oxygen bar", relies on technological means to transform the abstract air quality into perceivable and verifiable scientific indicators, playing an important supporting role in many fields such as ecolog...
In conventional understanding, atmospheric visibility is influenced by subjective factors, but it is essentially an objective phenomenon. In meteorology, this phenomenon is defined by optical path length: specifically, it refers to the distance a parallel light beam (emitted by an incandescent lamp...