Model:FT-CW48H
Brand:fengtu
Basic structure of fluorescent quantitative PCR instrument
The fluorescent quantitative PCR instrument is an instrument for real-time detection of reactions. It mainly consists of a gene amplification thermal cycle system, a fluorescence real-time detection system, a microcircuit control system, a computer and application software. Two of the core functional modules are: thermal circulation system and fluorescence real-time detection system. The working principle of the gene amplification thermal cycle system is basically the same as that of the traditional gene amplification instrument. It uses semiconductor heating and cooling to complete the thermal cycle process. The fluorescence detection system mainly consists of fluorescence excitation components, optical signal transmission components, fluorescence detection components, and control systems.
Fluorescent quantitative PCR instrument technical specifications
The "///" symbol indicates that the national standard currently does not define this indicator or mandatory requirement.
Indicator name | CW16H | CW32H | CW48H | |
Appearance | ||||
Overall dimensions | 235mm*385mm*175mm (width*depth*height) | |||
weight | 5.6kg | 5.7kg | 5.8Kg | |
Electrical parameters | ~220V/50Hz, 255W | |||
Data interface | USB 2.0 *2 (two on the right) | |||
Environmental parameters | ||||
Operating conditions | Temperature: 10-30℃, humidity: 20%~80% | |||
Shipping and storage conditions | Temperature: -20~55℃, humidity: 20%~80% | |||
Altitude | <2500 meters | |||
Noise level | A-weighted, <60dB | |||
Sample parameters | ||||
sample size | 16*0.2mL | 32*0.2mL | 48*0.2mL | |
Test tube type | Single tube, eight row test tubes | |||
sample volume | 15-100uL | |||
Temperature characteristics | ||||
Heating/cooling method | Semiconductor heating/cooling | |||
temperature range | 4℃-99℃ | |||
Maximum heating rate | ≥3.5℃/s | |||
average heating rate | ≥2.5℃/s | |||
Maximum cooling rate | ≥3.5℃/s | |||
average cooling rate | ≥2.5℃/s | |||
Temperature control accuracy | ≤±0.01℃ | |||
Temperature accuracy | ≤±0.1℃ | |||
temperature uniformity | ≤±0.3℃ | |||
Optical properties | ||||
Number of fluorescence detection channels | 4 channels | |||
Light emitting device | High brightness LED | |||
lighting devices | High sensitivity, high signal-to-noise ratio photodiode | |||
Adapter probe or dye | First channel: 470/520 FAM, SYBR Green | |||
Second channel: 530/570 HEX, JOE, VIC | ||||
Third channel: 580/610 ROX, CY3.5, Texas-Red | ||||
Fourth channel: 630/670 CY5 | ||||
Detection sensitivity | 1 copy | |||
Linear detection range | 100~1010 copies | |||
linear correlation coefficient | ≥0.999 | |||
Channel crosstalk | No crosstalk | |||
Test repeatability | ≤1.0% |
Main application fields of fluorescent quantitative PCR instrument
Foodborne pathogen testing
food safety
Animal and plant origin testing
Plant Science and Agricultural Biotechnology
Gene mutations and polymorphisms
animal diseases
basic scientific research
water body monitoring
Pathogen nucleic acid detection
GMO testing
Animal epidemic surveillance
Food hygiene and quarantine
Customs import and export quarantine
A rain gauge is an important device used to measure precipitation. With the continuous advancement of science and technology, the types of rain gauges have become increasingly diverse, among which the piezoelectric rain gauge has emerged as a "new favorite" in the market in recent years. B...
The Visibility detector is an intelligent meteorological monitoring device, mainly used for real-time monitoring of low visibility meteorological conditions, and is widely applied in fields such as transportation, meteorology, and environmental monitoring. This system, through the front-end visibili...
Traditional fixed visibility monitoring equipment is limited by factors such as installation location and power supply conditions, making it difficult to meet flexible and variable monitoring needs. The emergence of the Portable Visibility Detector has effectively solved this problem.Low visibility...
When we visit some parks and scenic areas, we often see an electronic screen on which real-time meteorological data, as well as negative oxygen ion and PM content, etc. are displayed. This is the Negative oxygen ion monitoring system.The Negative oxygen ion monitoring system can not only monitor the...