Shandong Fengtu IOT Technology Co., Ltd
Sales Manager:Ms. Emily Wang
Cel,Whatsapp,Wechat:+86 15898932201
Email:info@fengtutec.com
Add:No. 155 Optoelectronic Industry Accelerator, Gaoxin District, Weifang, Shandong, China

Sales Manager:Ms. Emily Wang
Cel,Whatsapp,Wechat:+86 15898932201
Email:info@fengtutec.com
Add:No. 155 Optoelectronic Industry Accelerator, Gaoxin District, Weifang, Shandong, China

Model:FT-YX432
Brand:fengtu
1、Meat discriminator Brief Introduction:
Meat discriminator is an efficient and convenient food testing device designed specifically for identifying the authenticity of meat. It can detect various animal-derived components, including pork, beef, lamb, horse meat, donkey meat, duck meat, and chicken. It can quickly and accurately detect DNA components in meat and meat-derived samples, ensuring the authenticity and reliability of the meat consumed. Its high sensitivity and low error rate guarantee the accuracy of the test results, providing professional testing services for various testing institutions.
2、Meat discriminator System Components
Meat discriminator consists of a four-channel, 32-well fluorescence quantitative PCR instrument and a portable accessory case.
3、Meat discriminator Working Principle:
Meat discriminator detects through real-time quantitative PCR technology, utilizing specific primers and probes to amplify and detect DNA in meat samples.
The detailed working steps are as follows:
1. Sample Preparation: The meat sample is homogenized, and DNA is extracted.
2. PCR Reaction: Specific primers, probes, and sample DNA are added to a reaction tube and placed in a detection instrument for PCR amplification.
3. Real-time Detection: During PCR amplification, the instrument monitors DNA amplification in real time through fluorescence signals, generating an amplification curve.
4. Data Analysis: Based on the fluorescence signal intensity and amplification curve, it is determined whether the sample contains the specific DNA sequence, thus determining the authenticity of the meat.
4、Meat discriminator Technical Specifications
1. Features a high-grade aluminum alloy sample holder with excellent thermal conductivity, corrosion resistance, and oxidation resistance, along with Peltier heating and temperature control, and a comprehensive sealing design. Neither sample solution nor condensation will leak into the Peltier temperature control element or other electronic components below the sample holder, effectively extending the instrument's lifespan.
2. Utilizes a high-precision PT1000 temperature sensor, achieving a temperature control accuracy of 0.01℃, ensuring precise temperature control.
3. Sample throughput: 0.2ml single tube, 0.2ml 8-tube strip.
4. Open reagent and consumable system: Compatible with reagents from any brand, suitable for standard 8-tube strips or 0.2ml PCR single tubes.
5. Employs four high-intensity, broad-spectrum, long-life LED solid-state light sources (blue, green, red, and yellow), ensuring strong light intensity across the entire spectral detection range, improving detection sensitivity. These LEDs generate no heat, have a long lifespan, and are maintenance-free for life.
6. High-sensitivity detector: Uses a high-sensitivity photomultiplier tube imported from Japan for higher detection sensitivity.
7. No optical path correction required: The scanning system ensures that the signal excitation and detection optical paths are completely consistent for each well, eliminating the need for optical path correction. This frees up a channel for correction, enabling true four-channel gene detection. ★
8. Number of channels: 4 channels.
9. Channel crosstalk: Uses high-precision narrow-band filters to greatly reduce channel crosstalk, and the software can also correct crosstalk parameters. 10. Detection Sensitivity: Capable of detecting single-copy DNA templates and clearly distinguishing between 1000 and 2000 copies of plasmid DNA.
11. Linear Detection Range: 10 orders of magnitude ★
12. Supports common fluorescent dyes and probe detection methods, such as SYBR Green I, Eva Green, Taqman, FRET, Molecular Beacons, Scorpions, Amplifluor, etc.
13. Module Temperature Range: 4-99℃
14. Control Mode: Built-in PCR operating system on the system screen or Windows computer ★
15. Interface: USB connection to computer
16. Operating Noise: Silent technology, maximum operating noise does not exceed 60dB during operation.
17. Operating and Analysis Software
17.1 Allows defining sample wells after running the program, saving experimental time.
17.2 Allows opening other experimental data results for viewing and analysis simultaneously while running the program.
17.3 The software automatically calculates the baseline range and sets the threshold line, providing users with reliable and accurate data results.
17.4 Experimental program settings and detection results can be directly printed as an experimental report, supporting export in multiple file formats and data styles such as XLS, CSV, and WORD ★
17.5 Results from the same batch of experiments can be grouped for independent data analysis, with up to 4 groups possible.
17.6 Provides both Chinese and English software interfaces. ★
17.7 The software can be installed on multiple computers without limitation, requiring no payment for usage rights, and offers free lifetime upgrades. ★
Meat discriminator Instrument Technical Specifications
| Basic performance | |
| Dimensions | 270*352*195(mm) |
| Weight | 7.3kg |
| Power supply | 220V |
| Power | Maximum working power 550w |
| Operating system | Comes with Android operating system |
| External computer | External Windows computer (Win7 system above) |
| System language | Real-time switching between Chinese and English |
| Communication interface | Square USB |
| Operating environment parameters | |
| Operating ambient temperature | 18~35℃ |
| Operating environment relative humidity | 0%~85% |
| Transport and storage temperature | -20~55℃ |
| Transport and storage relative humidity | 0%~85% |
| System performance | |
| Sample size | 32 holes*0.2ml |
| Sample volume | 15~100ul |
| Applicable consumables | 0.2ml single tube; 8×0.2ml rack tube |
| Temperature control range | 4~99℃ |
| Hot cover temperature | 30℃-108℃(default 105℃, hot cover temperature adjustable) |
| Temperature control method | High-performance imported semiconductors |
| Gradient temperature control | 3-module gradient temperature control, maximum temperature difference support 35℃ |
| Rise rate | 4.5℃/s(MAX) |
| Cooling rate | 3.4℃/s(MAX) |
| Temperature control accuracy | ±0.1℃ |
| Temperature homogeneity | ±0.25℃ |
| Temperature accuracy | ±0.1℃ |
| Functional operation | Pre-set projects and analysis parameters, easy to operate. |
| Report | Support report custom modules, 32-hole sub-project printing |
| Analytical function | Multiple qPCR data analysis functions, can detect 4 detection channels at the same time |
| Power-off protection | One-click restart of interrupted experiments |
| Instrument information | Have fault records, analysis, prompt functions, more convenient remote problem solving. |
| Analysis algorithm | Amplification curve, standard curve quantitative, melting curve, gene typing (SNP), relative quantification |
| Supporting HRM detection | Support |
| Data Export | The experimental results can be directly exported in the form of graphics and tables; the detailed content of the data report includes experimental conditions, data coordinates and tables, and data analysis parameters. |
| Data format | XLS, CSV, DOCX, PDF |
| TouchDown function | Support time and temperature increase and decrease mode |
| Fluorescence detection system performance | |
| Detection sensitivity | Detectable single copy genes |
| Dynamic range | 1~10^10 |
| Fluorescence repeatability | CV<1% (using a certain brand of reagents for the uniformity test of 32 holes, the Ct difference of 32 holes is kept within 0.5, and the CV is kept within 1%). |
| Correlation coefficient | 0.99~1 (three replicates for each concentration, the correlation coefficient of the standard curve >0.99, the amplification efficiency was maintained between 99%~101%) |
| Amplification efficiency | 99%~101% |
| Credibility | Distinguish 1000 from 2000 copy concentration differences |
| Laser light source | High power LED (maintenance free, long life) |
| Detector | High sensitivity photoelectric sensor |
| Excite and detect the transmission medium | High temperature resistant professional optical fiber |
| Excitation wavelength | 460nm~480nm, 525nm~545nm, 575nm~595nm, 600nm~620nm |
| Detect light wavelength | 505nm~525nm; 555nm~575nm; 600nm~620nm; 660nm~680nm |
Emergency meteorological monitoring refers to the rapid and accurate monitoring and analysis of relevant meteorological parameters during sudden meteorological disasters or emergency events. Its purpose is to provide timely and reliable meteorological evidence for emergency decision-making, so as to...
In our daily life, we often encounter severe weather such as haze and patchy fog. During these times, the atmospheric visibility is extremely low, just like a veil covering our eyes. It's a very unpleasant feeling, and such conditions are also prone to causing traffic accidents. So, is there a w...
Why choose a Portable Weather Station?First, it is small in size and light in weight, making it easy to carry to different locations. Whether for scientific research in remote mountainous areas, agricultural monitoring in vast farmlands, or rescue sites after natural disasters, a Portable Weather St...
Fengtu Technology is a supplier of weather station monitoring equipment. At present, the company has a variety of equipment, such as automatic weather stations, portable weather stations, handheld weather stations, weather sensors, etc., and also provides professional services....