Model:FT-QT4
Brand:fengtu
1. Ozone sensor technical parameters
| model | Measurement parameters | Measuring range | Accuracy | Resolution | unit | Operating temperature | Operating humidity |
| QT1 | Carbon monoxide | 0-1000PPM | ±2PPM | 1PPM | PPM | -20℃-+50℃ | 10-95%RH non-condensing |
| QT1S | 0-20PPM | ≤±5% | 0.01PPM | PPM | -20℃-+50℃ | 10-95%RH non-condensing | |
| QT2 | Sulfur dioxide | 0-20PPM | ±1PPM | 0.1PPM | PPM | -20℃-+50℃ | 10-95%RH non-condensing |
| QT2S | 0-1PPM | ≤±5% | 0.001ppm | PPM | -20℃-+50℃ | 10-95%RH non-condensing | |
| QT3 | Nitrogen dioxide | 0-20PPM | ±1PPM | 0.1PPM | PPM | -20℃-+50℃ | 10-95%RH non-condensing |
| QT3S | 0-1PPM | ≤±5% | 0.001ppm | PPM | -20℃-+50℃ | 10-95%RH non-condensing | |
| QT4 | ozone | 0-20PPM | ±1PPM | 0.1PPM | PPM | -20℃-+50℃ | 10-95%RH non-condensing |
| QT4S | 0-1PPM | ≤±5% | 0.001ppm | PPM | -20℃-+50℃ | 10-95%RH non-condensing | |
| QT5 | Oxygen content | 0~30%VOL | ±3%FS | 0.1%VOL | VOL | -20℃-+50℃ | 5-95%RH non-condensing |
| QT6 | Negative oxygen ions | 0~100,000/cm³ | ±10% | 10pcs/cm³ | Pieces/cm³ | +10℃-+70℃ | 10-70%RH without condensation |
| QT7 | Hydrogen sulfide | 0-100PPM | ±2PPM | 1PPM | PPM | -20℃-+50℃ | 10-95%RH non-condensing |
| QT8 | Methane | 0-100%LEL | ≤±3% | 1%LEL | LEL | -20℃-+50℃ | 10-95%RH non-condensing |
| QT9 | TVOC | 0-100PPM | 55±15 nA/ppm | 1PPM | PPM | -20℃-+50℃ | 10-95%RH non-condensing |
| QT10 | Ammonia | 0-100PPM | ±4PPM | 1PPM | PPM | -20℃-+50℃ | 10-95%RH non-condensing |
| QT11 | Nitric Oxide | 0-250PPM | -2~10PPM | 1PPM | PPM | -20℃-+50℃ | 10-95%RH non-condensing |
| QT12 | formaldehyde | 0-10PPM | <1PPM | 0.1PPM | PPM | -20℃-+50℃ | 10-95%RH non-condensing |
2. Ozone sensor product size diagram

In areas with clean air, the visibility can reach as high as 70-100 kilometers, but air pollution and humidity often reduce it. In areas with haze, fog, smoke, or in the places where sandstorms or forest fires occur, low visibility is extremely dangerous for transportation. Many serious accidents on...
Atmospheric environment monitoring sensors, as an important tool for monitoring physical and chemical parameters in the atmospheric environment, function by collecting real-time data on temperature, humidity, barometric pressure, wind speed, wind direction, and air quality. These sensors have a wide...
Visibility can be measured by visual observation, relying on manual inspection to estimate the visibility distance based on whether a certain reference object is visible. This method is simple and intuitive, but it is highly subjective and has poor standardization and objectivity.We recommend using...
Visibility, defined as the maximum horizontal distance at which a normal-sighted person can distinguish a target from its background, is a critical parameter in meteorology, transportation, environmental protection, and national defense.Early visibility measurements mainly relied on visual observati...