Model:FT-YYS04
Brand:fengtu
1. Drinking Water Monitoring Product Introduction
YYS04 Online Drinking Water Monitoring is an instrument that can monitor water temperature, pH, residual chlorine, and turbidity online. It integrates the corresponding sensors and measurement module communication storage, and can quickly and accurately record key parameters in the water body. At the same time, the instrument supports the expansion of water quality multi-parameter sensors, including but not limited to pH value, dissolved oxygen (DO), conductivity, turbidity, temperature, ammonia nitrogen, etc., which can be combined and configured according to different needs and applications, record and store historical monitoring data, alarm history records, and support historical data export.xlsx. The RS485 interface supports the MODBUS-RTU communication protocol to facilitate users to communicate freely with PLC, DCS, configuration software, DTU and other devices to connect and transmit data.
2. Application fields of Drinking Water Monitoring
Online Drinking Water Monitoring is widely used in the monitoring and control of various water bodies, including but not limited to the following areas:
1. Water plant: used to monitor the pH value, dissolved oxygen, turbidity and other parameters of tap water to ensure the safety and hygiene of tap water.
2. Groundwater monitoring: used to monitor groundwater parameters such as pH value, conductivity, temperature, etc., so as to detect and solve water quality problems in time.
3. River and lake monitoring: used to monitor the water quality of rivers and lakes, such as dissolved oxygen, turbidity, ammonia nitrogen and other parameters, so as to take timely pollution control measures.
4. Ocean monitoring: used to monitor the water quality of the ocean, such as salinity, dissolved oxygen, temperature and other parameters, so as to timely detect and control marine pollution.
5. Sewage treatment: used to monitor sewage water quality parameters, such as pH, COD, ammonia nitrogen, etc., in order to control and adjust the sewage treatment process.
6. Industrial production: used to monitor water quality in industrial production processes, such as pH, conductivity, dissolved oxygen and other parameters, so as to adjust the process in time and ensure product quality.
7. Scientific research: used for water quality monitoring in the field of scientific research, such as lake eutrophication, climate change, etc.
3. Technical Features of Drinking Water Monitoring
1. High reliability: suitable for long-term work in the field environment, stable measurement and strong anti-interference ability.
2. Flexible and portable: Each probe can be freely combined, replaced independently, and plug and play.
3. Scalability: Various sensors can be freely combined.
4. Multiple applications: on-site rapid measurement, emergency monitoring, or long-term online monitoring of groundwater, river water, lake water, and urban pipe network water.
5. Tough shell: ABS+PC material, corrosion-resistant, can work normally for a long time.
6. Compact structure: can be installed in small places.
7. Communication connection: RS485 expansion interface, master/slave interface isolation and independent communication.
4. Drinking Water Monitoring Technical Parameters
Display Output | 4.3-inch touch screen with strong LED backlight, can be operated under direct sunlight |
power supply | DC power supply: DC12V |
Power consumption | The power consumption of the instrument is about 12V/1W |
Sound Output | buzzer |
Communication Protocol | Standard RS485 Modbus-RTU protocol and device master/slave transmission channel support |
Main Materials | ABS+PC material |
Storage temperature | -20 to 70°C |
Operating temperature | -10 to 50°C |
Protection level | IP65 |
size | 175mm*140mm*49mm(length×width×height) |
weight | About 0.5KG |
5. Drinking Water Monitoring Sensor Configuration (optional)
Serial number | name | Measuring range | principle | Measurement accuracy | Configuration | Remark |
1 | temperature | 0~50℃ | High-precision digital sensor | ±0.3℃ | ✔ | |
2 | pH | 0~14 (ph) | Electrochemistry (Salt Bridge) | ± 0.1PH | ✔ | |
3 | ORP | -1500mv~1500mv | Electrochemistry (Salt Bridge) | ± 6mv | ||
4 | Conductivity | 0~5000uS/cm | Contact electrode method | ± 1.5% | ||
5 | Turbidity | 0~40NTU (low turbidity) | Scattered light method | ± 1% | ✔ | Optional |
0~1000NTU (medium turbidity) | Scattered light method | ± 1% | ||||
0~3000NTU (high turbidity) | Scattered light method | ± 1% | ||||
6 | Dissolved oxygen | 0~20mg/L | Fluorescence lifetime method | ± 2% | ||
7 | Ammonia nitrogen | 0~100mg/l | Ion Selective Electrode Method | ±1mg | ||
8 | Suspended Matter | 0~2000mg/L | Scattered light method | ±5% (depending on sludge homogeneity) | ||
9 | Residual chlorine | 0~5.00 mg/L | Ion Selective Electrode Method | ±5% of reading | ✔ | |
10 | Chloride ion | 0-3500.0mg/L | Ion Selective Electrode Method | ±5% | ||
11 | Total hardness | 0~1000.0mg/L | Ion Selective Electrode Method | ±10% of reading | ||
12 | cod | 0~500mg/L | UV254 absorption method | ±5% | COD and chlorophyll are equipped with automatic cleaners to prevent biological attachment and avoid light window pollution to ensure long-term monitoring is still stable; the automatic cleaning time and cleaning times can be set, and the power consumption is 0.7W | |
13 | Chlorophyll | 0~400ug/L | Fluorescence method | R2>0.999 |
Visibility is a crucial factor in our daily lives and the operations of numerous industries. Weather conditions such as heavy fog and sandstorms can significantly reduce visibility, causing serious impacts on transportation and travel, and are highly likely to trigger traffic accidents. In the aviat...
The Negative Oxygen Ion Detector can monitor the content of negative oxygen ions, the concentration of formaldehyde, and the value of PM2.5 in the air in real time and accurately. It is easy to operate and can be easily placed and used in homes, offices, or other indoor places. Through the intuitive...
Negative oxygen ions have many benefits for human health. It can help the ciliary movement of the respiratory tract, making sputum easier to cough up, alleviating the symptoms of respiratory diseases such as bronchitis and asthma. It can also regulate the nervous system, relieve tension and anxiety,...
The FT-WQX10B is an all-in-one anion sensor that integrates the monitoring of a wide range of meteorological elements, including anion, PM2.5, PM10, temperature, humidity, barometric pressure, oxygen content, noise, wind speed and wind direction. The highly integrated design of this sensor makes ins...