Model:FT-YYS05
Brand:fengtu
1. Drinking water monitoring system product introduction
YYS05 online Drinking water monitoring system is an instrument that can monitor water temperature, pH, residual chlorine, turbidity, and conductivity online. It integrates the corresponding sensors and measurement module communication storage, and can quickly and accurately record key parameters in the water body. At the same time, the instrument supports the expansion of multi-parameter water quality sensors, including but not limited to pH value, dissolved oxygen (DO), conductivity, turbidity, temperature, ammonia nitrogen, etc., which can be combined and configured according to different needs and applications, record and store historical monitoring data, alarm history records, and support historical data export.xlsx. The RS485 interface supports the MODBUS-RTU communication protocol to facilitate users to communicate freely with PLC, DCS, configuration software, DTU and other devices to connect and transmit data.
2. Application fields of Drinking water monitoring system
Online Drinking water monitoring system is widely used in monitoring and controlling various water bodies, including but not limited to the following areas:
1. Water plant: used to monitor the pH value, dissolved oxygen, turbidity and other parameters of tap water to ensure the safety and hygiene of tap water.
2. Groundwater monitoring: used to monitor groundwater parameters such as pH value, conductivity, temperature, etc., so as to detect and solve water quality problems in time.
3. River and lake monitoring: used to monitor the water quality of rivers and lakes, such as dissolved oxygen, turbidity, ammonia nitrogen and other parameters, so as to take timely pollution control measures.
4. Ocean monitoring: used to monitor the water quality of the ocean, such as salinity, dissolved oxygen, temperature and other parameters, so as to timely detect and control marine pollution.
5. Sewage treatment: used to monitor sewage water quality parameters, such as pH, COD, ammonia nitrogen, etc., in order to control and adjust the sewage treatment process.
6. Industrial production: used to monitor water quality in industrial production processes, such as pH, conductivity, dissolved oxygen and other parameters, so as to adjust the process in time and ensure product quality.
7. Scientific research: used for water quality monitoring in the field of scientific research, such as lake eutrophication, climate change, etc.
3. Technical features of Drinking water monitoring system
1. High reliability: suitable for long-term work in the field environment, stable measurement and strong anti-interference ability.
2. Flexible and portable: Each probe can be freely combined, replaced independently, and plug and play.
3. Scalability: Various sensors can be freely combined.
4. Multiple applications: on-site rapid measurement, emergency monitoring, or long-term online monitoring of groundwater, river water, lake water, and urban pipe network water.
5. Tough shell: ABS+PC material, corrosion-resistant, can work normally for a long time.
6. Compact structure: can be installed in small places.
7. Communication connection: RS485 expansion interface, master/slave interface isolation and independent communication.
4. Technical parameters of drinking water monitoring system
Display Output | 4.3-inch touch screen with strong LED backlight, can be operated under direct sunlight |
power supply | DC power supply: DC12V |
Power consumption | The power consumption of the instrument is about 12V/1W |
Sound Output | buzzer |
Communication Protocol | Standard RS485 Modbus-RTU protocol and device master/slave transmission channel support |
Main Materials | ABS+PC material |
Storage temperature | -20 to 70°C |
Operating temperature | -10 to 50°C |
Protection level | IP65 |
size | 175mm*140mm*49mm(length×width×height) |
weight | About 0.5KG |
5. Drinking water monitoring system sensor configuration (optional)
Serial number | name | Measuring range | principle | Measurement accuracy | Configuration | Remark |
1 | temperature | 0~50℃ | High-precision digital sensor | ±0.3℃ | ✔ | |
2 | pH | 0~14 (ph) | Electrochemistry (Salt Bridge) | ± 0.1PH | ✔ | |
3 | ORP | -1500mv~1500mv | Electrochemistry (Salt Bridge) | ± 6mv | ||
4 | Conductivity | 0~5000uS/cm | Contact electrode method | ± 1.5% | ✔ | |
5 | Turbidity | 0~40NTU (low turbidity) | Scattered light method | ± 1% | ✔ | Optional |
0~1000NTU (medium turbidity) | Scattered light method | ± 1% | ||||
0~3000NTU (high turbidity) | Scattered light method | ± 1% | ||||
6 | Dissolved oxygen | 0~20mg/L | Fluorescence lifetime method | ± 2% | ||
7 | Ammonia nitrogen | 0-1000.00mg/L (default) 0-100.00mg/l/ (customizable) | Ion Selective Electrode Method | 10% of reading, ±0.5℃ | ||
8 | Suspended Matter | 0~2000mg/L | Scattered light method | ±5% (depending on sludge homogeneity) | ||
9 | Residual chlorine | 0~5.00 mg/L | Ion Selective Electrode Method | ±5% of reading | ✔ | |
10 | Chloride ion | 0-3500.0mg/L | Ion Selective Electrode Method | ±5% | ||
11 | Total hardness | 0~1000.0mg/L | Ion Selective Electrode Method | ±10% of reading | ||
12 | cod | 0~500mg/L | UV254 absorption method | ±5% | COD and chlorophyll are equipped with automatic cleaners to prevent biological attachment and avoid light window pollution to ensure long-term monitoring is still stable; the automatic cleaning time and cleaning times can be set, and the power consumption is 0.7W | |
13 | Chlorophyll | 0~400ug/L | Fluorescence method | R2>0.999 |
Handheld Weather Stations need continuous upgrades to better meet diverse meteorological monitoring needs. The FT-SQ6+ has been upgraded in multiple aspects compared to its predecessor, the FT-SQ5.First, it offers a richer set of measurement parameters. The FT-SQ6+ adds measurements of average wind...
As an emerging instrument in the field of meteorological observation, the Portable Weather Station is gradually changing the way meteorological data is collected. It is small in size and light in weight, with extremely strong mobility, making it effortless to carry and transport. Whether it is for c...
The Clairvoyance water and rain query system is based on the Internet of Things technology, and realizes the function of water resources monitoring and early warning through the processing and analysis of the data acquisition module. The system conducts comprehensive management and data analysis of...
In the realm of tunnel operation management, ensuring driving safety and air quality is of paramount importance. The Tunnel Visibility Detector, as a specialized monitoring device, provides robust support for tunnel safety by accurately measuring carbon monoxide (CO) and visibility (VI).Poor v...