Model:FT-SS02
Brand:fengtu
1.Introduction to Blue Green Algae Test products
Blue Green Algae Test is an electrode method water quality analysis instrument that uses fully digital electrode detection to detect water quality parameters of chlorophyll and blue-green algae.The instrument is equipped with the self-developed ftiot operating system, which is simple to operate, has stable performance, accurate measurement, and wide detection range.It has a built-in high-capacity rechargeable lithium battery, making it convenient for users to conduct water quality testing at any time in the field or laboratory.
2.Blue Green Algae Test host parameters
| Charging input voltage | 4.5V-5.5V |
| Charging current | <2A |
| screen size | 3.5 inches |
| screen resolution | 480*800☆ |
| screen interface | MIPI DSI☆ |
| USB interface | 2 (Supports external expansion of mouse, keyboard, 4G, etc.)☆ |
| Type-C | 1 (Supports external expansion of mouse, keyboard, 4G, etc.)☆ |
| RS485 | 2 (Supports Modbus, json, asc input, etc.) |
| External sensor supply voltage | 12V |
| External sensor supply current | 1A |
| operating system | ftiot (based on Linux-5.4)☆ |
| CPU | 2*Cotex-A7, 650Mhz☆ |
| RAM | 512M DDR3☆ |
| Flash | 8G-64G |
| OpenGL | ES 2.0☆ |
| Wifi | support |
| 4G | Optional |
| button | support |
| capacitive touch screen | support |
| software architecture | B/S☆ |
| web access | Support☆ |
| MTP mode | Support☆ |
| Multiple terminal login | Support☆ |
| IPV6 | Support☆ |
| Sensor communication method | RS485, TCP, UDP, HTTP☆ |
| Data forwarding method | RS485, TCP, UDP, HTTP☆ |
| Remote SSH | Support☆ |
| remote debugging | Support☆ |
3.Blue Green Algae Test sensor parameters and configuration
| serial number | name | Measuring range | principle | Measurement accuracy | resolution | Configuration | Remark |
| 1 | temperature | 0~50℃ | High-precision digital sensor | ±0.3℃ | 0.01℃ | ||
| 2 | pH | 0~14(ph) | Electrochemistry (Salt Bridge) | ±0.1PH | 0.01 | ||
| 3 | ORP | -1500mv~1500mv | Electrochemistry (Salt Bridge) | ±6mv | 1mV | ||
| 4 | Conductivity | 0~5000uS/cm,0~10000uS/cm | contact electrode method | ±1.5% | 1uS/cm | ||
| 5 | TDS | 0-10000ppm 0-200ppt | contact electrode method | ±1.5%; ±0.1°C | 1ppm 0.01ppt | ||
| 6 | salinity | 0-10000ppm 0-200ppt | contact electrode method | ±1.5%; ±0.1°C | 1ppm 0.01ppt | ||
| 7 | Sludge concentration | 0~20.000g/L | scattered light method | ±5% (depending on sludge homogeneity) | 0.001g/L | ||
| 8 | Turbidity | 0~40NTU (low turbidity) | scattered light method | ±1% | 0.1NTU | Optional | |
| 0~1000NTU (medium turbidity) | scattered light method | ±1% | |||||
| 0~3000NTU (high turbidity) | scattered light method | ±1% | |||||
| 9 | Dissolved oxygen | 0~20mg/L | fluorescence lifetime method | ±2% | 0.01mg/L | ||
| 10 | Ammonia nitrogen | 0-1000.00mg/L (default) 0-100.00mg/l/ (customizable) | Ion selective electrode method | 10% of reading, ±0.5℃ | 0.01mg | ||
| 11 | suspended solids | 0~2000mg/L | scattered light method | ±5% (depending on sludge homogeneity) | 0.1mg/L | ||
| 12 | Residual chlorine | 0~5.00mg/L | Ion selective electrode method | ±5% of reading | 0.01mg/L | The accuracy is best when the flow rate is 0.42m/s-0.85m/s. | |
| 13 | Chloride ion | 0-3500.0mg/L | Ion selective electrode method | ±5% | 0.1mg/L | ||
| 14 | Total hardness | 0~1000.0mg/L | Ion selective electrode method | ±10% of reading | 0.1mg/L | ||
| 15 | cod | 0~500mg/L | UV254 absorption method | ±5% | 0.1mg/L | COD, chlorophyll, and blue-green algae are equipped with automatic cleaners to prevent biological adhesion and avoid light window pollution to ensure long-term monitoring is still stable; the automatic cleaning time and cleaning frequency can be set, and the power consumption is 0.7W | |
| 16 | Chlorophyll | 0~400ug/L | Fluorescence method | R2>0.999 | 0.01ug/L | ✔ | |
| 17 | blue-green algae | 0~200.0Kcells/mL | Fluorescence method | R2>0.999 | 0.1Kcells/mL | ✔ |
Scenic Area Lightning Warning System utilizes deployed atmospheric electric field meters to detect real-time fluctuations in electric field intensity. By integrating data from weather radar and lightning location systems, it enables localized, short-term warnings regarding lightning activity....
Wildfire dynamics are highly influenced by on-site meteorological conditions: wind speed and direction determine the fire’s spread path, while temperature affects both fire intensity and rescue safety. Real-time and accurate meteorological data serve as the "lifeline" for emergency respon...
Hydrological and environmental monitoring station is an automated monitoring device integrating Beidou-2 and Beidou-3 regional short message communication technologies. This device continuously monitors key hydrological parameters such as water level, flow velocity, flow rate, and rainfall, enabling hydrological data acquisition and disaster warning functions, and ensuring reliable real-time data transmission even in extreme environments....
Transmission line micro-meteorological monitoring stations are installed on power transmission towers to collect real-time meteorological parameters such as wind speed, wind direction, temperature, humidity, air pressure, and rainfall. This data is transmitted back to the monitoring center via...